Page 23For technical questions, please call 1-800-444-3353.SKU 68887
Contact Tip Inspection,
Cleaning, and Replacement
1. Make sure that the entire Gun is completely
cool and that the Power Cord is unplugged
from the electrical outlet before proceeding.
2. Remove the Nozzle as explained in the previous
subheading. Using the third oval hole on the Multi-
wrench, turn the Contact Tip counterclockwise
and slide it off the welding wire.
3. Scrub the exterior of the Tip clean with a wire brush.
Clean out the inside of the tip with a tip cleaner (sold
separately). Check that the Tip is the proper type for
the wire size used (.035″ tip for .030–.035″ wire).
4. Examine the shape of the hole at the end of
the Contact Tip. It should be an even circle; it
should not be oblong or have any bulges in it.
5. If any problems are noted, Contact Tip replacement
would be advisable. Make sure to select a
new Tip that is the correct size for the welding
wire used (.035″ tip for .030–.035″ wire).
6. Reinstall the Tip and securely
reinstall the Nozzle as well.
Gun
Nozzle
Contact
Tip